Labs · Rebar estimator

How much steel does my building need, and in which bar sizes?

For a 4-storey housing block of 250 m² per floor, allow about 40 tonnes of reinforcement (range 29 to 53 t), before structural design.

Inputs

Building use

Low and mid-rise buildings only: the tool applies the same steel per m² from 1 to 20 floors, which understates tall buildings.

m²
m
%

Result

Illustrative

—t

Estimated reinforcement (central value)

—t

Indicative range

—m²

Gross floor area

Indicative split by bar size
DiameterMassRelative shareCount (bars of 12 m)

Assumptions behind the estimate

AssumptionCentral valueRangeStatusSource
Reinforcement per m² of floor: Housing38 kg/m²28 – 50 kg/m²AssumptionCameroon Steel Labs planning assumption for a reinforced-concrete frame: reinforcement ratio of 80 to 110 kg per m³ of concrete × 0.35 to 0.45 m³ of concrete per m² of floor. Indicative; structural design sets the real value.
Reinforcement per m² of floor: Offices46 kg/m²35 – 60 kg/m²AssumptionCameroon Steel Labs planning assumption for a reinforced-concrete frame: reinforcement ratio of 100 to 130 kg per m³ of concrete × 0.35 to 0.46 m³ of concrete per m² of floor. Indicative; structural design sets the real value.
Reinforcement per m² of floor: Industrial55 kg/m²40 – 75 kg/m²AssumptionCameroon Steel Labs planning assumption for a reinforced-concrete frame: reinforcement ratio of 100 to 150 kg per m³ of concrete × 0.40 to 0.50 m³ of concrete per m² of floor. Indicative; structural design sets the real value.
Share of the mass by bar diameterØ8: 16%; Ø10: 18%; Ø12: 22%; Ø14: 12%; Ø16: 14%; Ø20: 10%; Ø25: 6%; Ø32: 2%—IllustrativeCameroon Steel Labs illustrative assumption, typical of a mid-rise reinforced-concrete frame; to be replaced by the project’s bar schedule.
Offcuts and laps (adjustable)5%0 – 15%AssumptionCameroon Steel Labs site assumption; depends on the lengths ordered and on the bending schedule
Density of steel7,850 kg/m³—SourcedEN 10080:2005, nominal mass basis: m = π/4 · d² · 7,850 kg/m³ = 0.006165 · d² kg/m

How this is calculated

Nominal mass per metre: m = 0.006165 · d² kg/m (d in mm), derived from the density of steel (7,850 kg/m³).

Reinforcement per m² of floor. For each building type, the range is the product of two planning assumptions given in the table: a reinforcement ratio (kg of steel per m³ of concrete) and a volume of concrete per m² of floor. The low end multiplies the two low values, the high end the two high values; the central value lies between them. Across the three types the assumptions run from 80 to 150 kg/m³ and from 0.35 to 0.50 m³/m², that is 28 to 75 kg per m²: every value the tool uses lies inside. The split by diameter, shown in the same table, is typical of a mid-rise building.

Calculation. Mass = floor area × reinforcement per m² × (1 + offcuts and laps); by diameter: mass × share of the diameter; number of bars = mass ÷ (mass per metre × bar length), rounded up.

Limit: this tool helps with budgets and purchase planning; it never replaces an engineer’s structural design.

Sources

  1. EN 10080:2005 and BS 4449:2005+A3:2016: nominal mass and tolerances of reinforcing steel
  2. Cameroon Steel, Labs method note (derived: steel density 7,850 kg/m³; assumed: planning intensities and split by diameter, shown in the table)